Scope of supply:
- Danfoss set impulse ABN
- Adaptor and set impulses ABN fa and VA
- Product instructions and operating instructions
- Work number: 193B2004
Functional description:
- Thermal set impulse (puttable implementation with spring connection)
- For valves and under-floor heating distributors suitable
- Position announcement and 360 degrees of assembly situation
- Maintenance-free
- Noiselessly
- Steckmontage
Technical information central device:
- Operating voltage: 24 volts
- Valve function: NO
- Without stream open
- Average achievement admission: 1.8 watts
- Frequency: 50 - 60 hertz
- Approach stream: 250 mA
- Surroundings temperature: From 25 to 50 °C
- Protective kind: IP 54
- Set strength: 100 N
- Connecting pipe: 0.75 mm ²
- Set way: min 4 mm
- Dimension (H x D): 53 x 47 mm
Danfoss link HC under-floor heating regulator
Product instructions and operating instructions
Work number: 014G0100
Functional description:
For the integration of wireless under-floor heating systems
Up to 10 exits (24 volts) for max. 13 set impulses of the under-floor heating
Suitable for NC or set impulses NO
Relay for pumps or kettle control
Automatic Seblstdiagnose to the announcement of different mistakes
Technical information central device:
Operating voltage: 230 V / Ac
Number of the exits and tension: 10 pieces / 24 volts
Transference achievement: <1 mW
Transference frequency: 868.42 MHz
Reach: 30 metres
Max load for pumps and kettle relay: 230 volts / 8 A
Cable length: 1.5 metres
Protective kind IP: 30
Dimension (L x H xT): 325 x 78 x 47 mm